An airport terminal and control tower under night lighting

Applications

Gas Fire Suppression Systems for Metro, Airport, and Mass Transit

Gas fire suppression in metro, airport, and mass transit facilities protects signaling, electrical, and communication rooms in underground and enclosed spaces where passenger density is high and evacuation options are limited.

Our engineers respond within 24-48 hours.

Why Gas Suppression?

Metro stations and airports are structures that hold large numbers of people at once, are often located underground or in enclosed volumes, and are complex to evacuate. A fire in this kind of environment makes evacuation harder due to sheer occupant density and reduces visibility quickly in underground spaces where smoke extraction is limited. These facilities are consequently classified among the highest-risk building types, making it essential to stop a fire at its source as early as possible.

A fire in critical operational spaces such as signaling rooms, communication systems, and electrical distribution cells may not pose a direct life-safety threat, but losing signaling capability can halt an entire line’s operation. Water-based suppression would cause permanent equipment damage and delay restart in these spaces; gas and in-cabinet suppression solutions instead protect them quickly and cleanly.

Sector-Specific Risks

In underground stations and terminal buildings, high passenger density extends evacuation time and increases panic risk in any fire scenario, which is why detection systems need to activate at a very early stage, while smoke is still limited. Limited evacuation routes and restricted natural ventilation are a structural disadvantage that amplifies the impact of both fire and smoke.

Electrical faults in signaling and communication rooms typically originate within dense cable and circuit-board assemblies and can be difficult to notice without dedicated monitoring. Train and carriage electrical compartments form a separate risk category requiring specialized design because they are both mobile and space-constrained; these compartments are usually protected with compact, in-cabinet suppression solutions coordinated with the vehicle manufacturer. Arcing risk in electrical distribution and transformer rooms, as in other sectors, stems from loose connections or overload and requires a fast, non-conductive extinguishing medium.

Trabzon Airport reference project

For train and carriage electrical compartments, signaling cabinets, and field equipment enclosures, panel suppression is the best fit thanks to its compact design and fast response time. For larger-volume signaling rooms, control centers, and technical buildings, room-flooding systems based on IG-541 or FM-200 are preferred; for large lines with multiple stations or technical spaces, a multi-zone architecture allows different points to be fed from a central cylinder bank.

Detection reliability in these facilities needs particular scrutiny given high passenger traffic and environmental noise (dust, vibration, humidity), which is why thorough functional testing during commissioning and ongoing supervision are essential to guaranteeing reliable performance under real operating conditions.

Typical fire hazards

#Hazard
1High passenger density in underground and enclosed spaces
2Limited evacuation routes and difficult smoke clearance
3Electrical faults in signaling and communication rooms
4Fire risk in vehicle electrical compartments (trains/carriages)
5Arcing in electrical distribution and transformer rooms

Systems considered for this application

SystemAgent familyOccupied spaces
In-Cabinet Gaseous Suppression System——
IG-541 (Inergen) Inert Gas Suppression SystemInert gas (52% N₂, 40% Ar, 8% CO₂)Suitable: within the NFPA 2001 concentration and exposure-time limits
FM-200 (HFC-227ea) Clean Agent Suppression SystemChemical clean agent (HFC)Suitable: design concentration below the NOAEL (9%), with alarm and evacuation
Fire Detection Systems——

Frequently asked questions

If a signaling room catches fire, is that a life-safety emergency for passengers?
Not directly — but losing signaling capability can halt an entire line's operation, which is why stopping the fire at its source as early as possible matters operationally even though the immediate risk to passengers in the station is separate from the risk inside the signaling room itself.
How is fire suppression handled inside a train or metro carriage's electrical compartment?
These compartments are mobile and space-constrained, forming a distinct risk category that's usually protected with compact, in-cabinet panel suppression solutions coordinated directly with the vehicle manufacturer, rather than a room-flooding system.
With high passenger traffic, dust, and vibration in a metro station, can the detection system still be relied on?
Detection reliability needs particular scrutiny in these environments precisely because of passenger traffic and environmental noise like dust, vibration, and humidity, which is why thorough functional testing during commissioning and ongoing supervision are treated as essential rather than optional.
Why does the detection system need to activate so early in an underground station?
High passenger density extends evacuation time and increases panic risk in any fire scenario, and smoke extraction is limited underground, so detection needs to trigger at a very early stage while smoke is still limited rather than waiting for a fully developed fire.
For an airport or metro line with multiple technical buildings, do we need a separate system at every location?
Not necessarily — for large lines with multiple stations or technical spaces, a multi-zone architecture allows different points to be fed from a central cylinder bank, while individual train compartments and field cabinets still use standalone panel suppression.

GYS is an Istanbul-based gas fire suppression company that runs the whole process in facilities like these with its own team, from survey to maintenance. Agent options and project steps are on our home page.

Let's choose the right system for your facility

List the rooms to protect and their approximate size. We select the agent by engineering calculation, based on occupancy, space and room integrity.